Skip to main content Skip to navigation
Human Th1/Th2/Th17 CBA Kit

BD™ Cytometric Bead Array (CBA) Human Th1/Th2/Th17 CBA Kit

(RUO)
Product Details
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
Human (QC Testing)
Flow cytometry (Routinely Tested)
RUO
AB_2869353


560484 Rev. 1
Components
Down Arrow Up Arrow
Description Quantity/Size Part Number
Human IL-2 Capture Beads 80 Tests (1 ea) 51-9005736 N/A
Human IL-10 Capture Beads 80 Tests (1 ea) 51-9005740 N/A
Human TNF Capture Beads 1 Each (1 ea) 51-9005724 N/A
Human IL-4 Capture Beads 1 Each (1 ea) 51-9005715 N/A
Human IFN-γ Capture Beads 1 Each (1 ea) 51-9005727 N/A
Human IL-6 Capture Beads 80 Tests (1 ea) 51-9005738 N/A
Human IL-17A Capture Beads 100 Tests (1 ea) 51-9006289 N/A
B Human Th1/Th2/Th17 PE Detection Reagent N/A 51-9006291 N/A
C) Human Th1/Th2/Th17 Cytokine Standards N/A 51-9006249 N/A
D Cytometer Setup Beads 1 Each (1 ea) 51-9005731 N/A
E1 PE Positive Control Detector 1 Each (1 ea) 51-9005732 N/A
E2 FITC Positive Control Detector 1 Each (1 ea) 51-9005734 N/A
F Wash Buffer 1 Each (1 ea) 51-2431KC N/A
G Assay Diluent 1 Each (1 ea) 51-2432KC N/A
BD(tm) CBA Serum Enhancement Buffer (H) N/A 51-9002150 N/A
560484 Rev. 1
Citations & References
Down Arrow Up Arrow

Development References (13)

  1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
  2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
  3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
  4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
  5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
  6. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
  7. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
  8. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
  9. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
  10. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). View Reference
  11. McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology). View Reference
  12. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
  13. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
View All (13) View Less
560484 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.