Perm Buffer II

BD Phosflow™ Perm Buffer II

Perm Buffer II
Flow cytometric analysis of ERK1/2 (pT202/pY204) in human PBMC.  Freshly isolated  human PBMC were either left untreated (unshaded histogram) or treated (shaded histogram) with 40 nM PMA at 37°C for 10 minutes. The PBMC were then fixed using BD Phosflow™ Fix Buffer I (Cat.No. 557870) and permeabilized with BD Phosflow™ Perm Buffer II (Cat. No. 558052) for 30 minutes on ice. After washing the cells twice with BD Pharmingen™ Stain Buffer (Cat. No. 554656/554657), the PBMC were stained with Alexa Fluor® 488 Rat Anti-ERK1/2 (pT202/pY204) (Cat. No. 512592).
Flow cytometric analysis of ERK1/2 (pT202/pY204) in human PBMC.  Freshly isolated  human PBMC were either left untreated (unshaded histogram) or treated (shaded histogram) with 40 nM PMA at 37°C for 10 minutes. The PBMC were then fixed using BD Phosflow™ Fix Buffer I (Cat.No. 557870) and permeabilized with BD Phosflow™ Perm Buffer II (Cat. No. 558052) for 30 minutes on ice. After washing the cells twice with BD Pharmingen™ Stain Buffer (Cat. No. 554656/554657), the PBMC were stained with Alexa Fluor® 488 Rat Anti-ERK1/2 (pT202/pY204) (Cat. No. 512592).
Product Details
Down Arrow Up Arrow


Description

BD Phosflow™ Perm Buffer II is intended to be used for the permeabilization of fixed PBMC's or lysed whole blood. PBMC's, for example, can be stimulated with kinase activators, such as phorbol esters, and can be fixed with BD Phosflow™ Fix Buffer I (Cat. No. 557870) followed by permeabilization of the cells with BD Phosflow™ Perm Buffer II to allow for an effective intracellular staining of kinases. Designed for optimal fluorescent staining in flow cytometry, BD Phosflow™ Perm Buffer II can be used with antibodies for phospho-protein analysis (i.e the staining of intracellular proteins involved in cell signalling pathways, such as phosphorylated proteins and assorted kinases). In many cases, these phospho-specific antibodies may be used simultaneously with the staining of cell surface markers (e.g CD markers). Not all cell surface markers, however, are compatible with BD Phosflow™ Perm Buffer II. For a current listing of compatible cell surface markers for use with BD Phosflow™ Perm Buffer II, investigators are encouraged to visit the following website: http://www.bdbiosciences.com/documents/antibodies_human_cellsurface_marker.pdf.

BD Phosflow™
Aqueous buffered solution containing proprietary ingredients.
AB_2869119
Intracellular staining (flow cytometry) (Routinely Tested)


Recommended Assay Procedures

Flow cytometry:

1. Warm BD Phosflow™ Fix Buffer I (Cat. No. 557870) to 37 °C prior to use.

2. Chill BD Phosflow™ Perm Buffer II to -20 °C prior to use.

3. Collect PBMCs after Ficoll-Paque separation and treat with any appropriate cell activators as applicable.

4. At the end of the treatment, immediately mix one volume of the warmed BD Phosflow™ Fix Buffer I with one volume of the PBMC suspension. Mix well and incubate the tubes in a 37 °C water bath for 10 min. Spin down the cells at 250 x g for 10 min in a table-top centrifuge and then aspirate the supernatant.

5. Wash the cells once with BD Pharmingen™ Stain Buffer (FBS) (Cat. No. 554656). Alternatively, 1X Washing/Staining Solution (1 x PBS, 1% FCS, and 0.09% sodium azide) may be used. Centrifuge to pellet the cells and remove the supernatant.

6. Vortex to loosen the cells. Permeabilize the cells by slowly adding cold BD Phosflow™ Perm Buffer II while vortexing. Incubate on ice for 30 min and then spin down the cells.

7. Wash the cells twice with 5-10 mL of BD Pharmingen™ Stain Buffer (FBS). Centrifuge at 250 x g for 10 minutes and remove the supernatant by aspiration.

8. Resuspend cells in BD Pharmingen™ Stain Buffer (FBS) at 1x 10^7/ml and aliquot 100 µl to each flow tube to continue with antibody staining and flow cytometric analysis.

Danger: BD Phosflow™ Perm Buffer II contains 64.86% methanol (w/w).

Hazard statements

Highly flammable liquid and vapor.

Toxic if swallowed, in contact with skin or if inhaled.

Causes damage to organs.

Precautionary statements

Keep away from heat/sparks/open flames/hot surfaces/ignition sources. - No smoking.

Keep container tightly closed. Ground and bond container and receiving equipment. Use explosion-proof [electrical/ventilating/lighting/] equipment.

Use non-sparking tools. Take action to prevent static discharges.

Wear protective clothing/eye protection/gloves.

Do not breathe mist/vapours/spray.

Use only outdoors or in a well-ventilated area. Wash thoroughly after handling. Do not eat, drink or smoke when using this product.

IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Take off immediately all contaminated clothing. Wash contaminated clothing before reuse.

IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

IF SWALLOWED: Immediately call a POISON CENTER/doctor. Rinse mouth. Call a POISON CENTER/doctor.

If exposed: Call a poison center/doctor

Store in well-ventilated place. Keep cool. Store locked up. Keep container tightly closed.

Static accumulating flammable liquid can become electrostatically charged even in bonded and grounded equipment.

Sparks may ignite liquid and vapor. May cause flash fire or explosion.

Use suitable extinguishing media to extinguish

Product Notices

  1. Ficoll-Paque is a trademark of Amersham Biosciences Limited.
  2. Alexa Fluor® is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  3. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  4. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  5. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
558052 Rev. 5

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.