Skip to main content Skip to navigation
Human Inflammatory Cytokine Cytometric Bead Array (CBA) - I Kit

BD™ Cytometric Bead Array (CBA) Human Inflammatory Cytokine Cytometric Bead Array (CBA) - I Kit

(RUO)
Product Details
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
Human (QC Testing)
Flow cytometry (Routinely Tested)
RUO
AB_2868941


551811 Rev. 1
Components
Down Arrow Up Arrow
Description Quantity/Size Part Number EntrezGene ID
A1 CXCL8/IL-8 Capture Beadss 1 Each (1 ea) 51-9005819 N/A
Human IL-1β Capture Beads 1 Each (1 ea) 51-9005821 N/A
Human IL-6 Capture Beads 80 Tests (1 ea) 51-9005738 N/A
Human IL-10 Capture Beads 80 Tests (1 ea) 51-9005740 N/A
Human TNF Capture Beads 1 Each (1 ea) 51-9005724 N/A
Human IL-12p70 Capture Beads 1 Each (1 ea) 51-9005823 N/A
C) Human Inflammatory Standards N/A 51-2553KC N/A
E1) PE Positive Control Detector N/A 51-2429KC N/A
E1 PE Positive Control Detector 1 Each (1 ea) 51-9005732 N/A
E2 FITC Positive Control Detector 1 Each (1 ea) 51-9005734 N/A
G Assay Diluent 1 Each (1 ea) 51-2432KC N/A
D Cytometer Setup Beads 1 Each (1 ea) 51-9005731 N/A
BD(tm) CBA Serum Enhancement Buffer (H) N/A 51-9002150 N/A
F Wash Buffer N/A 51-9004398 N/A
B Human Inflammation PE* Detection Reagent N/A 51-9004400 N/A
551811 Rev. 1
Citations & References
Down Arrow Up Arrow

Development References (13)

  1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
  2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
  3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
  4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
  5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
  6. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
  7. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
  8. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
  9. Fulwyler M, McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology).
  10. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
  11. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). View Reference
  12. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
  13. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
View All (13) View Less
551811 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.