BD CellView™ Image Technology

Sign up to receive educational content about spectral flow cytometry. Learn how to expand your view now.

 

Overview
Down Arrow

 

 

Overview

BD CellView Image Technology is real-time imaging (RTI) technology that combines flow cytometry data with spatial and morphological insights. The technology enables answering complex biological questions quickly, such as how cells grow, function and interact, or studying locations of viruses or proteins within a cell. The technology seamlessly integrates image and flow data on each event and can easily visualize the image for an event during acquisition. It enhances fluorescence activated cell sorting (FACS) with live visual inspection of target cells and novel gating strategies based on real-time image feature analysis using spatial distribution of fluorescence capabilities.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • subtitles off, selected
      See what you sort.
      Sort what you see.

      Listen to the conversation between Jochen Lamote, PhD and Jochen Behrends, PhD about BD CellView™ Image Technology. How BD CellView™ Image Technology is chaning their research?

      • Seeing is believing means you have a new perspective on the dots in your plots, increasing your sorting confidence.

      • Whether you are improving existing applications or developing new ones, CellView is there to address your scientific questions.

      • Where the signal originate is the key to develop new applications in various fields.

       

      Want to see more case studies?

       

      Download case studies

      Video Player is loading.
      Current Time 0:00
      Duration 0:00
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 0:00
       
      1x
        • Chapters
        • descriptions off, selected
        • subtitles off, selected

          BD CellView™ Image Technology versus camera-based imaging cytometry

          In contrast to camera-based technologies that combine imaging and flow cytometry, BD CellView™ Image Technology does not use a camera to image cells, which enables imaging at much faster rates. Camera-based technologies are limited by closely controlled fluidics and cannot be used for high-speed droplet cell sorting. BD CellView™ Image Technology implements orthogonal frequency domain multiplexing (OFDM) for imaging cells using electronic and optical components already used in flow cytometers. This method allows faster throughput than camera-based technologies. The image data can be acquired and quantified in real time at high speed for analysis and sorting as the sample is being acquired.

          Principles of BD CellView™ Image Technology

           

           

          Image Feature Definitions

           

          Eccentricity

           

          Eccentricity is a ratio of the shortest to the longest axis of the identified particle (as identified by the region of analysis)

           

          Usage examples: Doublet discrimination, cluster identification

           

          Availability: All imaging channels

          performance1

          Max Intensity 

           

          Max intensity is the intensity of the brightest pixel in the image. It is not affected by the region of analysis.

           

          Usage examples: Punctate fluorescence, phagocytosis assay, cell cycle analysis

           

          Availability: All imaging channels

          performance1

          Size

           

          Size is the number of pixels in the image, which are brighter than a user-defined pixel threshold.

           

          Usage examples: Label-free sorting, punctate fluorescence

           

          Availability: All imaging channels 

          performance1

          Radial Moment 

           

          Radial moment is the average distance of the pixels from the centroid within the region of analysis. 

           

          Usage examples: Doublet discrimination (with Eccentricity), cell—cell interactions (cellular synapse) 

           

          Availability: All imaging channels 

          performance1

          Correlation

           

          Correlation is the degree to which the location of two imaging channels are the same within the region of pixels defined by the region of analysis.

           

          Usage example: Translocation assay

           

          Availability: Any two imaging fluorescence channels

          performance1

          Delta Center of Mass

           

          The distance between two fluorescent signal sources in any two imaging channels within a particle as defined by the region of analysis.

           

          Availability: Any two imaging channels

          performance1

          Forward Scatter (FSC)

           

          As particles (cells) pass through the laser, the interaction of the light with the particle results in scatter in all directions.

           

          The forward scatter detector is placed in line with the laser path to measure light that is scattered at small angles. forward scatter loosely correlates to particle (cell) size.

          performance1

          Side Scatter (SSC)

           

          As particles (cells) pass through the laser, the interaction of the light with the particle results in scatter in all directions. 

           

          The side scatter detector measures light that is scattered perpendicular (90°) to the laser path. Side scatter loosely correlates to optical density or complexity of the particle.

          performance1

          Light Loss (Imaging)

           

          As particles (cells) pass through the laser, the interaction of the light with the particle results in scatter in all directions.

           

          Light loss is a measure of light (photons) lost from the laser due to scattering and absorption of light by a particle (cell). 

          performance1
          Sample Data