The fusion of safety, performance and sorting
The BD FACSAria™ Fusion Flow Cytometer combines sorting capabilities with best-in-class biosafety expertise for a comprehensive advanced cell sorter and biosafety solution.
The fully integrated biosafety cabinet meets emerging operator and sample protection requirements as well as many country standards for bioprotection. The instrument uses BD FACSDiva™ Software to efficiently control the setup, acquisition and analysis of flow cytometry data from the operator workstation. The software is common across many BD cell analyzers and cell sorters, making the BD FACSAria™ Fusion Flow Cytometer compatible with them.
Get more information from the BD FACSAria™ Fusion Flow Cytometer brochure.
FEATURES
The BD FACSAria™ Fusion Flow Cytometer’s proven dependability and ease of use puts the system in a class of its own
The BD FACSAria™ Fusion System is upgradable and backward compatible
- The flow cytometer has been verified to meet personnel and product protection standards for a Class II Type A2 biosafety cabinet and to meet many local standards
- Precisely integrated fluidic and optical systems maximize signal detection
- Optimized fiber-launched lasers improve sensitivity and resolution for each color in a multicolor assay
- The system can be expanded with additional lasers via a field upgrade. You can design a configuration that meets your lab’s budget and site requirements today and have a growth path for the future
Get more information about the optics, fluidics and electronics of the BD FACSAria™ Fusion Sorter from the system brochure.
BD FACS™ Accudrop Technology and software automation simplify drop-delay determination
- Once the drop-delay is calculated, the system automatically adjusts to maintain a constant break-off, called the Sweet Spot
- Automatic clog detection stops the sort and protects the collection tubes if a clog is detected
- After passing through the cuvette, the stream accelerates through the nozzle, and droplets are formed for sorting
- Since particle interrogation occurs above the nozzle, insertion and removal of the nozzle can occur without realigning the optics or the fluid stream
- BD FACS™ Accudrop Technology simplifies drop-delay determination
The BD FACSAria™ Fusion Flow Cytometer’s index sorting capability makes it possible to review the complete cell surface phenotype
- Complete cell surface phenotype of every cell sorted into a multiposition sort device, such as a 96-well tray
- Sort and tray position information available on an event-by-event basis according to the X and Y coordinates of the sort collection device
- Ability to precisely trace back post-sorting results to the flow characteristics of the specific cell
BD and Baker-designed cabinet meets biosafety standards and saves space
The Biosafety Cabinet (BSC) controls the direction, volume and speed of airflow to direct potentially harmful particles away from the operator
- The BD FACSAria™ Fusion Flow Cytometer can be purchased with or without a BSC. Since the flow cytometer and the BSC were designed for a seamless fit, a BSC can be added later in a field upgrade that takes less than a day to install
- The BSC protects the operator from aerosol exposure during a sort and the built-in and independently operated Aerosol Management System (AMS) also evacuates aerosols
- The enclosed sample-to-sort pathway, the Class II Type A2 biosafety cabinet and the Aerosol Management System make aerosol management fully redundant
- Since these systems are independent, they can be tested individually to ensure optimal operation and backup protection
PERFORMANCE