Alert : The site is undergoing maintenance. Some functionality including sign-in may be impacted
Saturday, February 21, 3:00 pm through Tuesday, March 03, 9:00 pm (PST), 2026
Ordering can continue through fax and phone.
Contact us
Alert : The site is undergoing maintenance. Some functionality including sign-in may be impacted
Saturday, February 21, 3:00 pm through Tuesday, March 03, 9:00 pm (PST), 2026
Ordering can continue through fax and phone.
Contact usAlert : The site is undergoing maintenance. Some functionality including sign-in may be impacted
Saturday, February 21, 3:00 pm through Tuesday, March 03, 9:00 pm (PST), 2026
.Ordering can continue through fax and phone.
Contact usThis page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}. You’re currently on the {originCountryName} site. Do you want to switch to a different country site?
BD FACSDiva™ Software is a collection of rich tools for flow cytometer and application setup, data acquisition, and data analysis that help streamline flow cytometry workflows for today's busy laboratory.
BD FACSDiva™ Software provides features to help users integrate flow systems into application areas, such as index sorting for stem cell and single-cell applications, as well as automation protocols for high-throughput and robotic laboratories.
Provides powerful index sorting, along with more routine software operation features including overlays, undo/redo, and multiple copying and pasting of all worksheet elements.
BD FACSDiva™ Software v9.0 and greater run on the Microsoft™ Windows™ 10 64-bit operating system. A selected list of BD FACSDiva™ Software features is listed in the following specification table.
The index sorting feature enables laboratories to sort cells into single wells of plates and also easily identify them on plots, in statistics views and in a detailed results file.
Learn more about Qr and Br in BD FACSDiva™ Software, the parameters for characterizing detector performance.
Index sorting
| Feature | Specification |
|---|---|
| Cytometers Supported | BD FACSCanto™ 10-color, BD FACSCelesta™, BD FACSCanto™, BD FACSCanto™ II, BD FACSAria™ II, BD FACSAria™ III, BD FACSAria™ Fusion, BD® LSR II, BD LSRFortessa™ and BD LSRFortessa™ X-20 |
| Options Supported | BD FACS™ Loader for the BD FACSCanto™ platform, BD® High Throughput Sampler for the BD FACSCanto™ and BD® LSR platforms, and BD FACS™ Accudrop for the BD FACSAria™ platform |
| Plates Supported | U, V and flat-bottom 96-well plates, flat-bottom 384-well plates, Terasaki plates (BD FACSAria™ Cytometer only) |
| Laser/Filter Support | 145 (See Table 1 in Qr and Br in BD FACSDiva™ Software: Parameters for Characterizing Detector Performance) |
| Event Display | User-Defined Event Number, User-Defined Percentage |
| Standard Gating | Interval, Rectangle, Polygon, Quadrants, Hinged Quadrants |
| Logical Gating | And, Or, Not, and Rest Of |
| Auto Gating | Auto-Polygon, Auto-Interval, Snap-To Polygon, Snap-To Interval |
| Standard Statistics | Minimum, Maximum, Geometric Mean, Mean, Median, Standard Deviation, Percent Coefficient of Variation, Mode |
| Robust Statistics | Robust Standard Deviation, Robust Percent Coefficient of Variation |
| Analysis Types | Manual or Batch |
| Plot Types | Histogram, 2D Dot Plot, 2D Contour Plot, 2D Density Plot |
| Plot Alignment Tools | Left, Right, Bottom, Top, Distribute Horizontally, Distribute Vertically |
| Performance Tracking Measurements | PMTV, Qr, Br, Bright Bead Target Value, Bright Bead %rCV, Mid Bead Median, Mid Bead %rCV, Dim Bead Median, Dim Bead %rCV, Forward Scatter Laser Delay, Fluorescence Laser Delay, Laser Current, Laser Power, Fluidics Pressure |
| Scaling | Linear, Log, Biexponential |
| Automated Setup | Define Baseline, Check Performance, Auto Compensation, Reset Target Values |
| Export Formats | JPG, TIFF, PNG, BMP, XML, CSV, PDF |
| Export Files | Experiments, FCS Files, Statistics, Templates |
| Levey-Jennings Plots | Up to 30 |
| Operating System | v9.0: Microsoft™ Windows™ 10 |
The software:
A single daily setup run using BD FACSDiva™ Software and BD FACSDiva™ CS&T Research Beads* supports consistency and accuracy of data acquisition.
Key cytometer setup values for PMT voltages, laser delay and area scaling factors are automatically calculated and adjusted to maintain optimal performance levels over time. This automation reduces startup time to approximately five minutes and eliminates multiple error-prone and expensive data acquisitions and calculations.
Note that because of a change in the beads for BD FACSDiva™ Software v7.0 and v8.0, upgrading from BD FACSDiva™ Software v6.x to v8.0 will cause a loss of existing baselines and application settings.
All baselines, performance checks and application settings will have to be recreated, as needed. See the BD FACSDiva Software Reference Manual and the BD Cytometer Setup and Tracking Application Guide for more details.
BD FACSDiva™ Software provides a graphic of the cytometer's physical optical configuration, showing the layout of detectors, filters and mirrors. This allows users to select the correct configuration for their work.
Administrators can create specialized configurations for particular applications by dragging filters, mirrors and fluorochromes onto a representation of the optical bench.
The software automatically tracks a wide range of performance metrics for each detector and laser in the system and displays the results in Levey-Jennings charts.
Alarm criteria can also be set to automatically notify users if performance metrics fall outside these boundaries.
BD FACSDiva™ Software helps users manage experimental details with easy-to-use interfaces and controls.
BD FACSDiva™ Software simplifies data acquisition with a dashboard that provides the tools for immediately viewing acquisition status and for setting acquisition stopping criteria. The application settings feature automatically adjusts voltage settings to daily changes in cytometer performance so that users can run existing applications more simply and quickly.
BD FACSDiva™ Software provides a wide array of basic analysis features enabling multiple applications to run on the BD FACSCanto™, BD® LSR and BD FACSAria™ Cytometers. These include gating tools to automatically find a population, biexponential scaling to completely see populations that might have negative relative fluorescence intensities, and even overlays to compare multiple tubes or samples.
Worksheets are configurable using predefined and customizable headers and footers. Snap-to grids allow for easy alignments of plots, comments and statistics. Previewing and PDF creation can be completed within the BD FACSDiva™ Software interface.
BD FACSDiva™ Software offers efficient data management tools to simplify data storage as well as improve organization of flow cytometer data. Along with built-in database and database utilities, BD FACSDiva™ Software provides automated data export in a variety of formats including XML, FCS and even ZIP, for multiple files concurrently. Manual export of FCS files creates an experiment folder structure in the operating system for easy identification of data files without the need to open them.
Performance
On a daily basis, BD FACSDiva™ Software automates tracking of all performance metrics, including detection efficiency, standard deviation of electronic noise, laser current and optical background. Viewing these metrics in interactive Levey-Jennings charts, administrators can visually adjust displays and time scales. The software allows notification when performance metrics fall outside specified boundaries for early troubleshooting and correction.
APPLICATIONS
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
BD flow cytometers are Class 1 Laser Products.
Microsoft, Windows and Excel are trademarks of Microsoft Corporation. Alexa Fluor and Pacific Blue are trademarks of Life Technologies Corporation. CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
The BD® Cytometer Setup and Tracking application and BD FACSDiva™ CS&T Research Beads are For Research Use Only. Not for use in diagnostic or therapeutic procedures.