抗体試薬
- フローサイトメトリー用試薬
-
ウェスタンブロッティング抗体試薬
- イムノアッセイ試薬
-
シングルセル試薬
- Accessories
- BD® AbSeq Assay | シングルセル試薬
- BD Rhapsody™ Accessory Kits | シングルセル試薬
- BD® Single-Cell Multiplexing Kit | シングルセル試薬
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits | シングルセル試薬
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit | シングルセル試薬
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
-
細胞機能評価のための試薬
-
顕微鏡・イメージング用試薬
-
細胞調製・分離試薬
- Dehydrated Culture Media
-
- Accessories
- BD® AbSeq Assay | シングルセル試薬
- BD Rhapsody™ Accessory Kits | シングルセル試薬
- BD® Single-Cell Multiplexing Kit | シングルセル試薬
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits | シングルセル試薬
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit | シングルセル試薬
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- Japan (Japanese)
-
Change country/language
Old Browser
BD™ DNA QC Particles


Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Product Details
Description
For use in the setup and verification of the doublet discrimination function of FACSCalibur™, FACSort™, or FACScan™ flow cytometers equipped with a doublet discrimination module (DDM) for DNA analysis, and for monitoring daily instrument performance.
For use with FACS® brand, and other, flow cytometers; all performance specifications will need to be determined for each individual case although the particles will meet the stability criteria as stated.
Contents: Chicken erythrocyte nuclei (CEN); calf thymocyte nuclei (CTN); instrument QC beads; propidium iodide solution.
Preparation And Storage
1. When stored at 2° to 8°C, the reagent is stable until the expiration date shown on the label. Do not use after the expiration date. Keep the reagent vials dry. 2. There is a tendency for the CEN (vial A) to settle during storage. This can be corrected by gently vortexing before use. Vortexing too vigorously will separate desired aggregates. It is critical that CEN be stored at 2° to 8°C, since these particles are sensitive to thermal degradation. 3. CTN (vial B) tend to aggregate during storage and should be vigorously vortexed to separate these aggregates. 4. The 2-µm beads (vial C) must be protected from prolonged exposure to light. 5. Do not expose stained CEN or CTN to prolonged light during storage or incubation. 6. Incubation times or temperatures other than those specified may lead to erroneous results. 7. Propidium iodide solution (vial D) must be protected from prolonged exposure to light. Deterioration in stain performance has been observed with short periods of room temperature storage, therefore stained samples must be stored at 2° to 8°C in the dark until analysis (maximum 12 hours).
Development References (7)
-
Barlogie B, et al. Flow cytometry in clinical cancer research. Cytometry. 1983; 43:3982-3997. (Biology: Flow cytometry).
-
Frankfurt OS, et al. Proliferative characteristics of primary and metastatic human solid tumors by DNA flow cytometry. Cytometry. 1984; 5:629-635. (Biology: Flow cytometry).
-
Hiddemann W, Schumann J, Andreef M, et al. Convention on nomenclature for DNA cytometry. Cytometry. 1984; 5:445-446. (Biology: Flow cytometry).
-
Kute TE, et al. Flow cytometry in solid-tumor prognosis. Lab Management. 1987; July:21-32. (Biology: Flow cytometry).
-
Larsen JK, et al. Flow cytometric discrimination of mitotic cells: resolution of M, as well as G1, S, and G2 phase nuclei with mithramycin, propidium iodide, and ethidium bromide after fixation with formaldehyde. Cytometry. 1985; 7:54-63. (Biology: Flow cytometry).
-
Ronot X, et al. G2 Arrest, binucleation, and single parameter DNA flow cytometric analysis. Cytometry. 1986; 7:286-290. (Biology: Flow cytometry).
-
Rose NR, et al. Manual of Clinical Laboratory Immunology 3rd ed. Washington, DC: American Society for Microbiology; 1986234.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not For Use in Diagnostic Procedures.
RUO/GMP—For Research Use Only. Not for use in diagnostic or therapeutic procedures. Although not required, these products are manufactured in accordance with Good Manufacturing Practices.
23-22943-00